Classroom Noise Meter

Press Start meter and allow the microphone: the gauge shows how loud the room is on a 0–100 scale, green when it is calm, amber as it gets louder and red when it passes your too loud line (70 by default). Sound is measured live on your device and never recorded.

  • Free
  • No sign-up
  • Projector mode
  • Audio never leaves your device

34 / 100

Nice and calm

Quiet streak 0:00 Best 0:00

Example reading. Press Start to measure your room.

Space starts and stops · Esc exits projector mode

Private: sound is measured live in this browser. Nothing is recorded, saved or sent anywhere.

Raise it if the needle barely moves when the class talks.

Green below 42, amber 42–69, red from 70.

Activity:

How to use the classroom noise meter

  1. Press Start meter and choose Allow when your browser asks to use the microphone.
  2. Let the class work normally for a minute and move the Sensitivity slider until normal working noise sits in the green.
  3. Set the Too loud at line for the activity, or tap a preset such as Silent reading or Group work.
  4. Press Projector mode so the class can see the face and gauge. Aim for a long quiet streak.

What is a classroom noise meter?

A classroom noise meter is an on-screen sound level monitor that shows students how loud the room is right now. It turns "please keep it down" into something everyone can see: a needle, a colour and a face that smiles when the room is calm. Students can check it themselves and adjust before you have to say anything.

How does this noise meter measure sound?

Your browser gives the page a live stream of numbers from the microphone, each between −1 and 1. Many times a second, the meter takes a short block of these samples and works out their root mean square (RMS), a standard measure of how strong a sound wave is. It converts that to a logarithmic scale, because our ears hear loudness logarithmically, and then maps it onto 0 to 100.

level = 100 × (20 × log₁₀(RMS) + sensitivity shift + 65) ÷ 55, kept between 0 and 100

The sensitivity slider shifts the scale by up to 20 decibels either way. The reading is smoothed so it rises quickly when noise starts and falls gently when it stops, which keeps the needle readable from the back of the room. A short clap will not trigger the alert: the level has to stay above the line for about half a second.

Is it measuring decibels?

No. The 0–100 level is relative, not a calibrated decibel (dB SPL) reading. Laptop microphones are tuned differently, and many reduce loud sounds automatically, so the same room can read differently on two devices. Use the meter to compare the room with itself ("quieter than a minute ago"), not to measure hearing safety. If you need real decibel readings, use a calibrated sound level meter.

This table shows how the microphone signal, in decibels relative to full scale (dBFS, where 0 is the loudest the mic can record), maps to the meter at three sensitivity settings. Zones assume the default "too loud" line of 70.

Mic signal (dBFS)Sensitivity 0Sensitivity 50Sensitivity 100Zone at 50
-650036Nice and calm
-5501855Nice and calm
-4503673Nice and calm
-35185591Getting louder
-253673100Too loud
-155591100Too loud
-1064100100Too loud

Tips for a quieter classroom

  • Agree the line together. Show the meter, let the class talk at "partner voice" level, and set the "too loud" line just above it.
  • Match the line to the task. Silent reading needs a low line, group work a higher one. The activity presets give you a starting point.
  • Reward the quiet streak. Set a goal, such as a 10-minute streak, and award a point on the classroom scoreboard when the class reaches it.
  • Keep the laptop in one place. Moving the microphone closer to a noisy table changes the reading more than the room does.
  • Turn the chime on only if needed. The flash is usually enough, and a sound can be distracting during tests.

Common problems

  • The needle does not move. Check that the right microphone is selected in your browser and that it is not muted. Raise the sensitivity.
  • It is always red. Lower the sensitivity, or move the laptop away from the loudest table or the projector fan.
  • The browser never asks for permission. The page must be opened over https, and some school devices block microphones. Try another browser or ask your IT team.

Organising the room as well? Make a seating chart that keeps chatty pairs apart, or split the class with the random group generator.

Frequently asked questions

How does the classroom noise meter work?

Press Start meter and allow the microphone. The page measures how loud the room is many times a second, smooths the result so the needle does not jump around, and shows it on a 0–100 scale with green, amber and red zones. When the level stays above your "too loud" line, the screen flashes as a gentle reminder.

Is the noise meter recording my class?

No. The sound is analysed live in your browser and only the loudness number is kept for a moment. No audio is recorded, saved or sent anywhere, and the microphone turns off when you press Stop or close the page.

Does it show decibels?

No. It shows a relative level from 0 to 100, not calibrated decibels. Every microphone and laptop picks up sound differently, so use the sensitivity slider to make normal working noise sit in the green zone, then set the "too loud" line where you want it.

Why does it say the microphone is blocked?

Your browser asked for permission and it was refused, or a school setting blocks the microphone. Click the microphone or lock icon in the address bar, choose Allow, and press Start meter again. On a managed school device, your IT team may need to allow it.

Can I use it without a microphone?

You need a microphone to measure the room. Most laptops have one built in; on a desktop computer, plug in a webcam or headset with a mic. Press "Try a demo" to see how the meter behaves with simulated classroom sound.

What is the quiet streak?

It counts how long the class has stayed below the "too loud" line, like a stopwatch. It starts again from zero each time the room gets too loud, and the best streak of the session is shown next to it. Many teachers set a target, such as 5 minutes of quiet work for a reward.

What sensitivity should I use?

Start at 50. If the needle sits in the red during normal chatter, lower the sensitivity; if it barely moves when the class talks, raise it. A laptop at the front of the room usually needs a higher setting than one near the students.